Table 4-1 (Page 5 of 11). Firmware Error Codes
Error Code Function /
Description
Repair Action/Possible Failing FRU
21A00001 Test Unit Ready
Failed - hardware
error
Refer to SCSI device error notes above
1. Replace SCSI device
2. Replace SCSI cable
3. Replace SCSI controller
21A00002 Test Unit Ready
Failed - sense data
available
Refer to SCSI device error notes above
1. Replace Media (Removable media devices)
2. Replace SCSI device
21A00003 Send Diagnostic
Failed
Refer to SCSI device error notes above
1. Replace SCSI device
21A00004 Send Diagnostic
Failed - DevOfl cmd
Refer to SCSI device error notes above
1. Replace SCSI device
21E00xxx SCSI Tape Refer to 21A00xxx error codes for a description and
repair action for the specific “xxx” value.
21ED0xxx SCSI Changer Refer to 21A00xxx error codes for a description and
repair action for the specific “xxx” value.
21EE0xxx Other SCSI device
type
Refer to 21A00xxx error codes for a description and
repair action for the specific “xxx” value.
21F00xxx SCSI CDROM Refer to 21A00xxx error codes for a description and
repair action for the specific “xxx” value.
21F20xxx SCSI Read/Write
Optical
Refer to 21A00xxx error codes for a description and
repair action for the specific “xxx” value.
Network Controller problem
22000001 Internal wrap test
failed.
Replace the card.
22001001 Internal wrap test
failed.
Replace the card.
22010001 Adapter failed to
complete hardware
initilization.
Replace the card.
22011001 Adapter failed to
complete hardware
initilization.
Replace the card.
22020001 Adapter failed to
complete hardware
initilization.
Replace the card.
Memory Controller problem
25000000 Memory controller
failed
Replace System Planar
Flash Update problem
Chapter 4. Error Code to FRU Index for the Model 150 4-5