IBM RS/6000 7043 43P Home Theater Server User Manual


 
Table 4-3 (Page 12 of 13). Firmware Checkpoints
Checkpoint
(hex)
Description Repair Action
E206 Look for PRISM on
PCG and switch to
50MHz
1. Replace System Planar
E207 Setup Data gather
mode and 64/32-bit
mode on PCG
1. Replace System Planar
E208 Assign bus number
on PCG
1. Replace System Planar
E209 Assign PCI I/O
addresses on PCI
1. Replace System Planar
E20A Assign PCI I/O
addresses on PCG
1. Replace System Planar
E20B Check MCERs stuck
at fault
1. Replace System Card
E20C Testing L2 cache 1. Replace CPU Card
E210 Processors L1 data
cache array test
fails. System Hangs.
1. Replace System Planar
E211 IPL ROS CRC
checking
1. Replace System Planar
E212 Processor POST 1. Replace CPU Card
E213 Initial memory
configuration
See “MAP 1240: Memory Problem Resolution” on
page 2-12
E214 Memory test See “MAP 1240: Memory Problem Resolution” on
page 2-12
E216 Copy ROS into
RAM. Setup
Translation and C
environment
1. Replace Memory Card
E21A System has some
good memory
1. See “Unresolved problems” on page 4-27
E220 Final memory
configuration
See “MAP 1240: Memory Problem Resolution” on
page 2-12
E240 Setup Winbond ISA
bridge
1. Replace System Planar
E241 Reset PCI Bus 1. Replace System Planar
E242 Initialize ISA DMA
channel
1. Replace System Planar
Chapter 4. Error Code to FRU Index for the Model 150 4-25