JVC TDR6 TV Receiver User Manual


 
Using a Remote Unit
01-0870-401B 01/03 31
4
Using a Remote Unit
In addition to the front panel, a remote unit can be used to configure and monitor
the TDR6. The chapter presents the following information for remote command
operation:
Configuring remote software parameters
Overview of remote communications
Instructions for issuing remote commands
Error messages
Remote command listing
For remote cabling information, refer to Chapter 2.
Any parameter changes made using a remote unit are not automatically stored in flash memory.
When the TDR6 configuration is changed using a remote unit, an operational test should be
performed to verify that the system is operating correctly. Then the new configuration should be
saved by issuing the MC CONFIG SAVE command.
If the TDR6 is reset prior to issuing the MC CONFIG SAVE command, any changes made using the
remote unit will not be restored. Instead, the TDR6 restores the last changes saved to flash memory.
Once the configuration is saved using the MC CONFIG SAVE command, the TDR6 automatically
restores the saved settings when the unit is reset or powered up.
Configuring Remote
Software Parameters
Remote Port
After you have cabled the remote unit to the TDR6 remote port, perform the
following steps to establish remote communications:
1. Configure the communications software parameters of your remote unit to
match the following TDR6 remote port factory DVB default settings:
Baud rate = 38400 bps
Data bits = 8
Parity = none
Stop bits = 1
Unless you change the remote control settings and save the changes in
non-volatile (flash) memory, the TDR6 restores this list of default
communications settings whenever the TDR6 is reset or powered-up.
2. Press the Enter key on the remote keyboard several times to generate a prompt
(>) on the remote display. Once a prompt appears on the remote display,
successful communication has been established between the TDR6 and the
remote unit.
Once communications are established, the remote port parameters can be
changed to a faster operating speed.
3. If you are unable to generate a prompt on the remote unit, troubleshoot the
remote unit installation and setup:
Ensure that the remote unit and the TDR6 are turned on and plugged into
an active AC outlet
NOTE