44 01-0870-401B 01/03
Using a Remote Unit
PGCA TIMEOUT Time in seconds — Query-only; displays the amount of time that the service
originator allows the TDR6 to remain authorized to receive
the selected service in the event that the TDR6 stops
receiving periodic service authorization messages.
Front panel equivalent: Details>PGCA>Timeout on loss
UD
x
where
x
= A or B
— — Combined with additional mnemonics, specifies the user
data port that is the object of the command.
When UDx is entered, the TDR6 returns the following user
data information: PID, auto select, source, interface type,
handshake, config mode, baud rate, data bits, parity, and
stop bit settings.
Front panel equivalent: None
UD
x
AUTO On, Off On Sets how PIDs are selected.
■ On: TDR6 selects the lowest incoming PID
■ Off: Operator must enter the PID manually using the UD
x
PID command
Front panel equivalent: None
UD
x
BAUD_ASYNC 1200, 2400, 4800, 9600,
19200, 38400
38400 Query-only; displays the baud rate for the specified
asynchronous user data port.
Front panel equivalent: Details>Data>Data A/B>Baud
(when data is asynchronous)
UD
x
BAUD_SYNC 0 TO 4096000 38400 Query-only; displays the baud rate for the specified
synchronous user data port.
Front panel equivalent: Details>Data>Data A/B>Baud
(when data is synchronous)
UD
x
DATA 7, 8 8 Query-only; displays the data bits for the specified
asynchronous user data port.
Front panel equivalent: Details>Data>Data A/B>Data Bits
(when data is asynchronous)
UD
x
HANDSHAKE On, Off Off Sets the handshaking parameter for the specified user data
port:
■ On: Enables handshaking for the specified user data port
■ Off: Disables handshaking for the specified user data port
Front panel equivalent: None
UD
x
INTERFACE EIA-232; EIA-422 EIA-232 Sets the hardware interface for the specified user data port
to be either EIA-232 or EIA-422 compliant.
Front panel equivalent: Details>Data>Data A/B>Interface
UD
x
PARITY None, Odd, Even None Sets the parity for the specified asynchronous user data
port.
Front panel equivalent: Details>Data>Data A/B>Parity
(when data is asynchronous)
UD
x
PID <available PIDs> or Off 0x0030 Sets the PID for the specified user data port.
When no user data is present, the system returns the
message
no data present
.
To query all available user data PIDs, enter the command
UD
x
PID ?
Front panel equivalent: Details>Data>Data A/B>PID
UD
x
SOURCE — — Query-only; displays the source (synchronous or
asynchronous), and baud rate of the user data at the input
to the encoder. For asynchronous user data, also displays
the number of data bits and the number of stop bits.
When no user data is present, the system returns the
message
no data.
Front panel equivalent: Details>Data>Data A/B>Source
UD
x
STOP 1, 2 1 Sets the stop bits for the specified asynchronous user data
port.
Front panel equivalent: Details>Data>Data A/B>Stop Bits
(when data is asynchronous)
TDR6 Remote Command Listing (continued)
Mnemonics
Parameters/
Response Values
DVB Defaults Description