JVC TDR6 TV Receiver User Manual


 
Using a Remote Unit
01-0870-401B 01/03 43
MC DEFAULT RESTORE
<
strin
g>
where <
strin
g> = DVB,
Default1, Default2, and
Default3
Resets the TDR6 with the specified factory-default operating
configuration.
For more information on configurations, refer to the
configuration chapter.
Front panel equivalent: Config>Default>Restore
MC ETHERNET IP ADDRESS <
x.x.x.x
> where each
x
represents a decimal
number from 0 to 255
Sets the ethernet IP address for the TDR6. Example:
192.200.9.201
Front panel equivalent: Control>Network>Address
MC ETHERNET IP
GATEWAY
<
x.x.x.x
> where each
x
represents a decimal
number from 0 to 255
0.0.0.0 Sets the IP gateway address.
Front panel equivalent: Control>Network>Gateway
MC ETHERNET IP MAC Format:
<
xx:xx:xx:xx:xx:xx>
where xx is a
hexadecimal number
from 0tof.
Sets the Ethernet hardware address.
For example: 00:e0:74:00:02:cb
MC ETHERNET IP MASK <
x.x.x.x
> where each
x
represents a decimal
number from 0 to 255
255.255.255.0 Sets the IP address mask (IP subnet mask).
Front panel equivalent: Control>Network>Mask
MC HW OPTS Query-only; displays the optional hardware installed on the
controller card.
Front panel equivalent: None
MC HW TYPE Query-only; displays the type of decoder hardware.
Front panel equivalent: None
MC RS232 BAUD 1200, 2400, 4800, 9600,
19200, 38400
38400 Sets the baud rate for the remote port.
Front panel equivalent: Control>EIA-232>Baud
MC RS232 DATA 7, 8 8 Sets the data bits for the remote port.
Front panel equivalent: Control>EIA-232>Data Bits
MC RS232 HARDFLOW On, Off On
On: sets data flow to be controlled by hardware
Off: permits data flow to be controlled by hardware
Front panel equivalent: Control>EIA-232>Hard Flow
MC RS232 PARITY None, Odd, Even None Sets the parity for the remote port.
Front panel equivalent: Control>EIA-232>Parity
MC RS232 SOFTFLOW On, Off Off
On: sets data flow to be controlled by software
Off: permits data flow to be controlled by software
Front panel equivalent: Control>EIA-232>Soft Flow
MC RS232 STOP 1, 2 1 Sets the stop bits for the remote port.
Front panel equivalent: Control>EIA-232>Stop Bits
MC SW Query-only; displays the installed software version.
Front panel equivalent: Version
PGCA When PGCA is entered, the TDR6 returns the following
conditional access information: mode, status, authorization,
and time-out
Front panel equivalent: None
PGCA AUTHORIZATION Yes, No, N/A Query-only; displays whether the originator of the service
has authorized your TDR6 to receive the selected service.
Front panel equivalent: Details>PGCA>Authorization
PGCA MODE Auto Auto Sets the TDR6 to automatically receive authorized PGCA-
protected signals.
Front panel equivalent: None
PGCA STATUS In_the_Clear,
PGCA_Enabled
Query-only; displays whether or not a signal is PGCA
protected.
Front panel equivalent: Details>PGCA>Status
TDR6 Remote Command Listing (continued)
Mnemonics
Parameters/
Response Values
DVB Defaults Description