Mitsubishi Electronics DX-TL5000U DVR User Manual


 
61
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
•“Main-Alarm appears when Alarm Recording Area
(System Menu
Memory Data Management Setting
for Main Memory Change Partition Setting) is set to
other than 0 %.
•“Main-LPA appears when Long Pre-Alarm Area
(System Menu
Memory Data Management Setting
for Main Memory
Change Partition Setting) is set to
other than 0 %.
step3. Set the desired capacity.
Set the remaining capacity of each device to
output signal.
Call Out Settings
This item is used to output warning signals from the CALL
OUT terminal to the device connected when the capacity
becomes full or reaches to the specified value.
Call Out Settings
2
Setup Menu
System
Rear Terminal Setting
4
3
step1. Set the desired capacity for each area.
Off: Does not output a signal.
•“Alarm Recording Area can be set when Alarm
Recording Area (System Menu Memory Data
Management Setting for Main Memory Change
Partition Setting) is set to other than 0 %.
•“LPA Recording Area can be set when Long Pre-
Alarm Area (System Menu
Memory Data
Management Setting for Main Memory Change
Partition Setting) is set to other than 0 %.
Call out settings use the photo-coupler output to
decrease the malfunctions due to wiring. See CALL
OUT signal output (
see page 18) for the correct
connection.
For the relationship between the warning display and
CALL OUT signal output, see pages 114 and 115.
The warning display of the item written Fixed in the
CALL OUT output column displays unconditionally.
For the item written Selectable in the CALL OUT
output column, you can set the condition that CALL
OUT signal is output. For example, the buzzer can
be set to sound when reaching the value set in
Normal Recording Area, Alarm Recording Area,
LPA Recording Area, or Copy 2 (Setup
Menu System Rear Terminal Setting Call Out
Settings) when Buzzer (Setup Menu System Rear
Terminal Setting) is set to Warning.
Key Sound
This item is used to make a sound when using the opera-
tional buttons, JOG dial, and SHUTTLE ring.
Setup Menu
System
Rear Terminal Setting
4
3
step1. Set the key sound to on or off.
Buzzer
This item is used for a buzzer to sound when the remain-
ing main or copy 2 device capacity reaches the value set in
Low Memory Alarm Setting (Setup Menu System Rear
Terminal Setting
Mode Out Settings). Other than the
above, it is possible to set the buzzer to sound when start-
ing alarm recording or emergency recording, or when a
warning is displayed.
To sound a buzzer only when reaching a specified remain-
ing HDD capacity:
1) Set Buzzer to Remain.
2) Set the remaining capacity in Low Memory Alarm Set-
ting (Setup Menu
System Rear Terminal
Setting Mode Out Settings).
To sound a buzzer when reaching the specified remaining
HDD capacity and when a warning is displayed:
1) Set Buzzer to Warning.
2) Set the remaining HDD capacity in the Call Out Set-
tings. (Setup Menu
System Rear Terminal
Setting Call Out Settings ).
Setup Menu
System
Rear Terminal Setting
4
3
step1. Set the desired buzzer setting.
SETTING
BUZZER
When reaching the remaining
capacity set in Low Memory
Alarm Setting
When a failure occurs and
a warning is displayed
When an alarm recording or
emergency recording is started
When controlling the buzzer to be
sound via the personal computer
Remain
ON
OFF
OFF
OFF
Warning
OFF
ON
OFF
OFF
Alarm
OFF
OFF
ON
OFF
LAN
OFF
OFF
OFF
ON
Off
OFF
OFF
OFF