LAN B (Communication) Setting
This item is used to make the communication settings between
this unit and the PC connected via LAN B.
System Menu
COM/LAN1
LAN B (Communication) Setting
Alarm Notification Detailed Infomation
D
3
LAN B Address Setting
1
Service Port Setting
2
E-mail Notification Information
3
IP Alarm Notification Information
4
step
2
step
7
step
1
step
3
step
5
step
6
E-mail Notification Detailed Infomation
D
step
4
(LAN B Address Setting)
step1. Set the IP address, sub net mask, and Gateway.
• MAC address is shown on the bottom of the
screen of <LAN B (Communication) Setting>.
• Do not assign the same IP address or network address
for LAN A and LAN B.
• Do not assign “000.000.000.000” to IP address and
broadcast address. If this address is assigned,
communications or any other functions of this unit may
not be performed correctly.
• The setting cannot be changed during recording. Stop
recording before changing the setting.
(Service Port Setting)
step2. Set the port setting of “Web,” “User Access,” and
“Administrator.”
• This item is used to set the port number which is
necessary to connect a PC.
• Normally, leave the setting as is.
• Do not change the setting without sufficient knowledge
about the network setting.
• When making the settings other than the port settings
of “Web,” “User Access,” and “Administrator,” using
the specified application is required. Consult your
dealer about the specified application.
(E-mail Notification Information)
step3. Check the settings of “E-Mail Address” and
“Recorder ID.”
• When selecting “Mail,” the e-mail is sent for the
selected address.
• Using the web function of this unit is required to input
“E-Mail Address” and “Recorder ID.”
(E-mail Notification Detailed Information)
step4. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining
capacity reaches the value set for Call out setting.
Temp/Fan: Transmits signal when the high
temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is rebooted.
Record: Transmits signal when the recording is
started.
Alarm: Transmits signal when the alarm recording
is started.
Sensor: Transmits signal when the signal is input
to the terminal on the rear panel.
• Using the web function of this unit is required to
change the contents to be transmitted.
(IP Alarm Notification Information)
step5. Check the settings of “IP Address” and “Target Port.”
• This item is used to transmit warning signals or
signals of status change such as a closure of a
rear terminal to the PC connected.
• When selecting “Test,” the sending test for the
set IP address and port is executed.
• Using the specified application is required to change
the IP address and target port. Consult your dealer
about the specified application.
• Transmission of signal to broadcast address is not
supported.
(Alarm Notification Detailed Information)
step6. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining
capacity reaches the value set for Call out setting.
Temp/Fan: Transmits signal when the high
temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is rebooted.
Record: Transmits signal when the recording is
started.
Alarm: Transmits signal when the alarm recording
is started.
Sensor: Transmits signal when the signal is input
to the terminal on the rear panel.
• Using the specified application is required to change
the contents to be transmitted. Consult your dealer
about the specified application.
step7. Select “Return” in the screen of <LAN B
(Communication) Setting>.
• When the setting of “IP Address,” “Sub Net Mask,”
“Gateway,” or “Service Port Setting” is changed,
the power turns off automatically and then the
unit restarts.