Mitsubishi Electronics DX-TL5000U DVR User Manual


 
74
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
This menu is used to set the communication settings be-
tween this unit and the external device connected.
RS-232C Setting
This item is used to remotely control this unit via a PC con-
nected to the RS-232C terminal.
RS-232C Setting
1
COM/LAN
1
System Menu
step1. Select the communication mode.
Remote A: Controls this unit via a PC and this unit
returns every status information.
Remote B: Controls this unit via a PC and this unit
returns only the response to the command code.
Remote C: Controls this unit via a PC and this unit
returns nothing.
Off: Does not control this unit via a PC.
step2. Set the port settings shown below.
Transmission mode
Data bit length
Parity bit
Stop bit length
Delimiter
Set all the settings to the same values as the PC
connected.
COM/LAN System Menu
RS-485 Cascade Setting
This item is used to make the settings for the cascade func-
tion using the recorders connected via the RS-485 termi-
nal.
RS-485 Cascade Setting
2
COM/LAN
1
System Menu
step1. Select the cascade connection mode of this unit.
Standalone: Does not perform the cascade
function.
Cascade: Performs the cascade function.
step2. Select the recorder address.
Master ID:01: Sets this unit as the master recorder
for the cascade function.
Slave ID:01 to 16: Sets this unit as the slave
recorder for the cascade function.
•“Recorder Address displays only when the Cascade
Connection Mode is set to Cascade.
Do not set cascade address which is overlapped with
that of other recorders.
When operating cascade function via keyboard, set
all the recorders to slave. (When there is the recorder
of which cascade address is Master ID:01, the
cascade function may not operate correctly.)