ZyXEL Communications EOC350 VCR User Manual


 
Chapter 13 Troubleshooting
EOC350 Series User’s Guide
76
2 Check that the:
Termination system and termination adapter have the same privacy key. Unmatched privacy keys
make it impossible for termination adapters to send/receive data to/from the termination
system. (The Web Configurator EP Management screen shows a red background for unmatched
termination adapters.)
Host limit for each termination adapter is not zero. If the host limit of the termination adapter is
0 (zero) or the IN port is disabled, the termination adapter is not allowed to send/receive data.
IN port for each termination adapter is not disabled.
3 Check the physical connection quality between the termination system and each termination
adapter by diagnosis tools.
4 If the connection quality is not good enough, please review the whole coax segment.
Check the wiring topology does not have amplifiers.
Check the total path attenuation, including mixers, combiners, splitters and taps.
Check for noise sources.
5 Check the firmware version of the termination system and termination adapters.
I cannot transmit/receive data between termination adapters.
For security, termination adapters can’t communicate directly with each other.
I cannot reach high speed communication.
1 Check the bandwidth control settings, or the maximal throughput of your WAN service.
2 Check your physical connection quality.
13.4 Resetting the EOC350-TS to Factory Defaults
If you reset the EOC350-TS, you lose all of the changes you have made. The EOC350-TS re-loads
its default settings, and the username/password resets to admin/1234. You have to make all of
your changes again.
You will lose all of your changes when you reset the EOC350-TS to its factory defaults.
To reset the EOC350-TS,
1 Make sure the power LED is on.