Fostex PD-6 DVD Recorder User Manual


 
86
PD-6
DVD Location Recorder (Chapter 6: TC Setup mode)
<User>
MMDDYYxx
DDMMYYxx
BOTH
TC
UBIT
flashing
flashing
User bit setting of internal generator time code
You can set the time code user bit of the internal generator, which is output
from the [TIME CODE OUT] connector when the [TC OUT] switch is set to
“GEN”.
1. Select the “Gen Ubit: ******” menu and press the [ENTER] key.
The display shows the current internal time code generator setting information,
in which the currently selected user bit output mode flashes (the default mode
is <User>:00 00 00 00>.
2. Use the [SEL] dial to select the desired user bit, and press the [ENTER] key.
the default is 00 00 00 00.
BG_76:MM (month)/ BG_54:DD (day)/ BG_32:YY (year)/ BG_10:ff (US)
BG_76:DD (day)/ BG_54:MM (month)/ BG_32:YY (year)/ BG_10:ff (EUR)
3. Press the [EXIT] key to exit the TC Setup mode.
Jam mode setting
You can set the jam mode which determines what information is jammed.
1. Select the “JAM mode: ****” menu and press the [ENTER] key.
The display shows the current internal time code generator setting information,
in which the jam mode flashes (the default mode is “BOTH”).
2. Use the [SEL] dial to select the desired mode, and press the [ENTER] key.
3. Press the [EXIT] key to exit the TC Setup mode.
Both time code and user bit are jammed.
Only time code is jammed. For the user bit, the external time code data is
used.
Only the user bit is jammed. For the time code, the external time code data
is used.