iRMC S2/S3 307
Console Redirection - Redirecting the console
Enable Local Monitor Off
This option allows you to activate the following options:
– In full-control mode of an AVR session, you can switch the local
monitor on and off (AVR Extras menu, see page 102).
–For users with administrator or OEM permissions, the toggle
button Turn Off / Turn On is also enabled. This also allows the local
monitor to be switched on and off (see figure 188).
Figure 188: Advanced Video Redirection page - Local Monitor On / Off
– You can also configure that the local monitor is switched off
automatically for the duration of an AVR session when an AVR
session is started (see the Automatic Local Monitor Off when AVR is
started option).
I If no concurrent session with Local Monitor Off is active, the local
monitor is automatically switched on again when the AVR session
is closed.
Automatic Local Monitor Off when AVR is started
I This option only takes effect if Enable Local Monitor has been
activated.
If you activate this option, the local monitor is automatically switched off
for the duration of the session when an AVR session is started. After the
AVR session is closed, the local monitor is automatically switched on
again if no concurrent session with Local Monitor Off is active.
I Parallel AVR sessions:
Even if you switch on the local monitor during your AVR session
(in the AVR menu Extras or with the Turn On button), the local
monitor is automatically switched off again if a new, concurrent
AVR session is started.
The local monitor is switched on again automatically when all AVR
sessions have been closed.
Ê Click Apply to activate your settings.