364 iRMC S2/S3
Updating firmware images
Proceed as follows:
I An online update using a USB memory stick is described below (see
section "Setting up the USB memory stick" on page 357).
Ê Connect the USB memory stick to the managed server.
Ê In the Windows command line or the Linux Command Line Interface (CLI)
switch to the drive corresponding to the USB memory stick.
Ê Set the firmware selector to the value 4 by calling the flash tool with the
parameter /s 4.
E.g., in the Windows command line you enter:
WinFLIRMCS2 /s 4
Ê Start the update of the firmware and the SDR data by calling the flash tool
with the corresponding update files.
E.g., in the Windows command line you enter:
WinFLIRMCS2 dcod<firmware-version>.bin <nnnnnnn>.sdr /i
During the firmware update, the console informs you about the progress of
the update operation. If an error occurs, the update operation is aborted and
a corresponding return code is reported (see page 370).
Ê Restart the managed server. This automatically activates the firmware
image with the updated firmware.