Configuring the iRMC S2/S3 via SCCI and scripted configuration
12.2.2 Scripted configuration of the iRMC S2/S3
This section describes provides information on the following topics:
SCCI commands supported by the iRMC S2/S3.
Using various script languages for scripted configuration of the iRMC S2/S3.
Generating encrypted passwords with the iRMC_PWD.exe program.
12.2.2.1 List of SCCI commands supported by the iRMC S2/S3
The SCCI commands supported by the iRMC S2/S3 are shown in table 19:
SCCI OpCode SCCI Command String Description
0xE002 ConfigSpace ConfigSpace Write
0x0111 PowerOnCabinet Power On the Server
0x0112 PowerOffCabinet Power Off the Server
0x0113 PowerOffOnCabinet Power Cycle the Server
0x0204 ResetServer Hard Reset the Server
0x020C RaiseNMI Pulse the NMI (Non Maskable Interrupt)
0x0205
RequestShutdownAndOff Graceful Shutdown, requires running
Agent
0x0206 RequestShutdownAndReset Graceful Reboot, requires running Agent
0x0209 ShutdownRequestCancelled Cancel a Shutdown Request
0x0203 ResetFirmware Perform a BMC Reset
0x0250
ConnectRemoteStorageServer Connect or Disconnect a standalone
Remote Storage Server
Table 19: SCCI commands supported by the iRMC S2/S3