iRMC S2/S3 395
IPMI OEM Commands supported by the iRMC S2/S3
12.1.2.4 SCCI-compliant signaling command
10 02 - Write to System Display
This command is used to write characters to the LocalView display (if
connected).
Request Data - B8 NetFnlLUN: OEM/Group
- 10 Cmd : Command Group Fan Test
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4 02 Command Specifier
5 Object Index: : Line on Display to write on.
6:7 Value ID (not used)
8 Length Number of characters to write, incremented by
one. (The string need not be null-terminated; characters
exceeding the length of a display line are truncated.)
9 Attribute:
0 = Write String left aligned.
1 = Write String centered.
10:10+n Characters to write to the display; string need not be null-
terminated.
Response Data - BC
- 10
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first