366 iRMC S2/S3
Updating firmware images
Recovery _L
A recovery flash for firmware image 1 (low firmware image) is carried out.
In the case of a recovery flash, the flash is performed for all three areas
of firmware image 1 without any version check.
Recovery _U
A recovery flash for firmware image 2 (high firmware image) is carried out.
In the case of a recovery flash, the flash is performed for all three areas
of firmware image 2 without any version check.
Readme
The Readme file is opened.
Reboot
An iRMC S2/S3 warm start is performed.
English / German
Specify keyboard layout. German is set by default.
Ê Start the required update variant by clicking on the corresponding button.
During the firmware update, the console informs you about the progress of
the update operation. If an error occurs, the update operation is aborted. A
corresponding return code is reported (see page 370).
Ê Once the update operation has been completed, click on Exit, to close the
FlashDisk menu.
Ê Remove the USB memory stick from the managed server.
Ê Restart the managed server (e.g. with [Ctrl]+[Alt]+[Del]).