Power Switch
Switches the power on or off. The OPERATE ON mode is
automatically activated when the power is switched on.
(Page 16)
* Make sure the system has been set in the OPERATE
OFF mode before switching off the power supply.
[AC IN(220V - 240Vto)] Power Input Terminal
Connect using the power cable supplied to an AC 220 -
240 V outlet. (Page 16)
[VIDEO OUT] Terminal (BNC)
This function is the same as the [VIDEO OUT] terminal on
the front panel.
[SPOT OUT] Terminal (BNC)
Outputs live images screens. Also enables different
contents from the [VIDEO OUT] to be output. (Page 26)
[VIDEO IN] Camera Image Signal Input (BNC)
Connect this to the video output of the video camera (sold
separately.)
[THRU OUT] Camera Image Output Terminal (BNC)
Output camera image signals that support the various
[VIDEO IN] terminals. Also enables monitor televisions to
be connected (automatic terminals.)
[AUDIO IN] Terminals 1 and 2 (RCA)
Connect this to the audio output terminal of the device from
which audio signals are to be recorded.
[AUDIO OUT] Terminal (RCA)
This function is the same as the [AUDIO OUT] terminal on
the front panel.
[VGA OUT] VGA Output Terminal (D-SUB 15PIN)
Outputs live images, playback images and the menu
screens. Outputs the same contents as [VIDEO OUT].
(Page 24)
[LAN] Connection Interface (100 Base-T)
For connection to the Intranet and other networks using a
LAN cable. (Page 65)
[RS-232C] Remote Terminal (D-sub 9PIN)
Enables the VR-509 to be controlled from an external
source when connected to a personal computer or other
device.
* See page 114 for details on the RS-232C interface.
[SERIAL] Serial Terminal (USB A-TYPE Female)
This port has the same function as the SERIAL port on the
front panel.
Signal Input/Output Terminal
For operating VR-509 using external alarm signals or
signals received from external devices, or for operating
external devices by outputting signals. (Page 13)
* Diameter of applicable cables: AWG 22 to 28.