JVC VR-509E DVR User Manual


 
Recording Camera Images
32
1. Take a note of all the [OPERATION SET] data settings
(F.RATE, QLY and M.DET on NORMAL REC/ALARM
REC) when [STANDARD] or [REC PATTERN 1 to 9] is
in use.
2. Amend the setting for the number of operation
cameras with [INTRODUCTION SET] as explained on
page 20.
3. When the [INTRODUCTION SET] parameters have been
amended with procedure #2, reset the [OPERATION
SET] data settings that were listed in procedure #1.
1. Press the [MENU] button.
The [MENU] [DETAIL OPERATION] [OPERATION
SET] [OPERATION] screens will be displayed in this
sequence in accordance with the [MENU Screen
Operations] explained on
page 17
.
2. Select your desired item with the [S/T] keys, and then
change the value of the setting with [–/+].
Settings
Sets whether or not to perform recovery recording after a power
failure.
OFF: Remains at OFF.
COMPULSION REC:Normal recording is started.
PRIOR STATE: Recording is started in accordance with
the same settings prior to the power failure
only when recording was being carried out
before the power failure occurred.
Sets whether or not to illuminate the recording indicator during
recording.
OFF: Not illuminated.
ON: Illuminated.
Sets the operations to be carried out when the hard disk runs
out of space.
OFF: Recording is stopped.
ALARM LOCK:
Recording is continued while overwriting old recordings.
However, the alarm log (including emergency and
passcode error recording) will not be overwritten.
ALL: Recording is continued while overwriting all old logs.
* Details on REPEAT REC are provided on page 104.
3. Press the [SET] button.
The confirmation screen will be displayed.
4. Select “SAVE” with [W/X], and then press the [SET].
Setting the Operation Set (continued)
Procedure for Changing the Number of Cameras
Operation Setup (RECOVERY REC, REC
INDICATOR, REPEAT REC)
RECOVERY REC
REC INDICATOR
REPEAT REC
OPERATION
2.
RECOVERY REC
REC INDICATOR
REPEAT REC
OPELOCK RELEASE
OPERATION LOCK
REC STOP
PLAY
CHANGE SETTING
CHANGE MONITOR
OPERATION
DVD
OFF
ON
OFF
BASIC
OFF
OFF
OFF
OFF
OFF
OFF
OFF