Recording Camera Images
34
1. Press the [MENU] button.
• The [MENU] → [REC DETAIL] → [ALARM REC] screens
will be displayed in this sequence in accordance with the
[MENU Screen Operations] explained on
page 17
.
2. Select the camera input that is to be set up with [W/X].
3. Select your desired item with the [S/T] keys, and then
change the value of the setting with [–/+].
Settings
10 SEC, 15 SEC, 30 SEC, 1 MIN, 3MIN, 5MIN:
Alarm recording is performed only for the period of
time set.
MANUAL: Recording is continued during the period a signal is
being input.
OFF: Pre-alarm recording is not performed.
10 SEC, 30 SEC, 60 SEC:
Pre-recording is performed only for the period of time set.
4. Press the [SET] button.
• The confirmation screen will be displayed.
5. Select [SAVE] with the [W/X] keys, and then press
[SET].
* Pre-alarm recording is only performed for alarm detection
when ALARM REC has been set and recording is not being
carried out at that time.
Details on pre-alarm recording are provided on page 105.
* Alarm recording that includes motion detection will not be
carried out when the setup menu is open.
Alarm recording is stopped when [ALARM RESET] is pressed
and when a signal is input to the [ALARM RESET] terminal
during alarm recording (signal input terminal, motion detection.)
Press [ALARM RESET] during alarm recording.
• Alarm recording will be stopped.
Input a signal to the [ALARM RESET] terminal during
alarm recording.
• Alarm recording will be stopped.
* Set the frame rate for [ALARM REC] at anything other than
[--] for [INTRODUCTION SET-3] or [OPERATION SET] when
alarm recording is to be carried out.
(Page 21, 31)
* There are cases where the search time during playback will
require additional time if the number of alarms is increased.
It is recommended that the formatting process is carried out
when the number of alarms exceeds 100,000.
Setting ALARM Recording
DURATION
PREALARM REC
ALARM REC
3.
2.
CAM NO
DURATION
PREALARM REC
MOTION DETECT SET
DYNAMIC SENSITIVITY LEVEL (DEFAULT-8)
STOP LEVEL (DEFAULT-2)
(DEFAULT-2) TARGET AREA LEVEL
MOTION DETECT AREA SET ..
1
3MIN
10SEC
8
2
2
Ending ALARM Recording
Canceling the Alarm with the Button on the
Front Panel
Canceling the Alarm with the Signal Input
Terminal