Recording Camera Images
1. Press the [MENU] button.
Opens the menus in accordance with the instructions
provided in MENU Screen Operations (page 17) in the
sequence of “MENU” “DETAIL OPERATION”
“OPERATION SET”.
2. Select your desired mode with [S/T], and then press
the [SET] button.
The “REC PATTERN SET” screen will be displayed.
The amount of time that recording is possible in
accordance with the set parameters will be displayed on
the bottom line.
The amount of time recording is possible with the
remaining hard disk capacity will be displayed when the
[REPEAT REC] parameter is set at [OFF]. The amount
of time recording is possible with the total capacity of the
hard disk will be displayed when the [REPEAT REC]
parameter is set at [ALL] or [ALARM LOCK].
* The above is an example of STANDARD.
3. Select “NORMAL REC” with [S/T/W/X], and then select
the frame count and resolution with [–/+].
Settings
0.08, 0.2, 0.4, 0.8, 1.7, 2.5, 5, 8.3, 12.5, 25:
Sets the number of frames (images) to be recorded per
second.
---: Does not record.
H (High): High resolution recording
N (Normal): Normal resolution recording
B (Basic): Basic resolution recording
L (Long): Long-term resolution recording
4. Select “ALARM REC” with [S/T/W/X], and then select
“QTY” “F.RATE” or “M.DET” with [–/+].
Settings
0.8, 1.7, 2.5, 5, 8.3, 12.5, 25:
Sets the number of frames (images) to be recorded
per second.
---: Does not record
(AUTO): Records with the highest frame count possible when
there are no effects from other inputs.
Highest frame count: The maximum frame count that
can be used for recording divided equally.
A guide to the estimated recordable frame rate is
displayed on the right-hand side of the [AUTO]
display when all alarm recordings have been started.
H (High): High resolution recording
N (Normal): Normal resolution recording
B (Basic): Basic resolution recording
L (Long): Long-term resolution recording
Sets the M.DET sensitivity.
OFF: Disables the M.DET mode.
NORM: Detects the M.DET sensitivity in normal mode.
USER: Detects the M.DET sensitivity in free mode.
DOOR H, DOOR L, HALL H, HALL L, CHECK H, CHECK L,
ATM H, ATM L, LOBBY H, LOBBY L, GATE H, GATE L, PARK
H, PARK L, DARK H, DARK L, ELEVATR, COUNTER:
Detects the M.DET sensitivity in set mode.
* See page 35 for more details.
5. Press the [SET] button.
A confirmation screen will be displayed.
6. Select “SAVE” with [W/X], and then press the [SET]
button.
It is necessary to ensure that the total number of frames
shown below in (1) to (3) are set so that they do not
exceed 100 (or 50). The total number of frames are 100
when the [PRIORITY] setting on the [INTRODUCTION
SET-1] screen (See page 20) is set at [SMOOTH], and
50 when it is set at [HIGH RESOLUTION].
(1) Total number of frames during normal operations.
(2) Total number of frames during alarm recording.
(3) Total number of frames of either each camera,
normal operations or alarm operations,
whichever is the largest.
Setting the Operation Set
F.RATE
QTY
OPERATION SET
2.
STANDARD ..
REC PATTERN1 ..
REC PATTERN2 ..
REC PATTERN3 ..
REC PATTERN4 ..
REC PATTERN5 ..
REC PATTERN6 ..
REC PATTERN7 ..
REC PATTERN8 ..
REC PATTERN9 ..
STANDARD
3.
F.RATE(ips) (AUTO) QLY M.DET
NORMAL REC
CAM 4
CAM 5
CAM 6
CAM 7
CAM 1
CAM 2
CAM 3
CAM 8
CAM 9
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
N
N
N
N
N
N
N
N
N
H
H
H
H
H
H
H
H
H
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
42h
RECORDABLE HOUR
ALARM REC
F.RATE(ips) QLY
4.
F.RATE
QTY
M.DET
Restrictions on the Settings for Frame Rate