JVC VR-509E DVR User Manual


 
Recording Camera Images
36
When the [Motion Detection] value on the [OPERATION SET]
screen is set at [USER], it is possible to set the sensitivity for
[DYNAMIC SENSITIVITY LEVEL], [TARGET AREA LEVEL]
and [STOP LEVEL]. These settings have no effect if anything
other than [USER] has been specified.
1. Press the [MENU] button.
The [MENU] [REC DETAIL] [ALARM REC] screens
will be displayed in this sequence in accordance with the
[MENU Screen Operations] explained on
page 17
.
2. Select the camera input that is to be set up with [W/X].
3. Select your desired item with the [S/T] keys, and then
change the value of the setting with [–/+].
Settings
The level value for detection. The higher the value, the higher
the sensitivity .
Setting Range:
1 (low sensitivity) to 10 (high sensitivity)
The level value for the size of the subject to be detected. The
higher the value, the more difficult it is to detect small motions.
Setting Range:
1 (small) to 10 (large)
The offset value for the level of operation sensitivity. The larger
the value, the more difficult to discontinue alarm detection.
Setting Range:
1 to 3
4. Press the [SET] button.
The confirmation screen will be displayed.
5. Select [SAVE] with the [W/X] keys, and then press
[SET].
Use the manual settings if the desired level of detection is not
attained with STANDARD or OTHER SCENE. These three
parameter values should be determined after referring to [Table
#1: Parameters for Each Scene] and [Table #2: Target Area
Level and Detection Area Count] on page 35.
Motion Detection with Freely Determined
Sensitivity Levels
DYNAMIC SENSITIVITY LEVEL
TARGET AREA LEVEL
STOP LEVEL
ALARM REC
3.
2.
CAM NO
DURATION
PREALARM REC
MOTION DETECT SET
DYNAMIC SENSITIVITY LEVEL (DEFAULT-8)
STOP LEVEL (DEFAULT-2)
(DEFAULT-2) TARGET AREA LEVEL
MOTION DETECT AREA SET ..
1
3MIN
10SEC
8
2
2
Manual Setup