34
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•
Various recording settings (continued)
4. Turn the JOG dial to move the cursor to A-REC DURATION
and turn the SHTTLE ring to the right.
• The sub-item will start flashing.
5. Turn the JOG dial to display “15S” and turn the SHUTTLE
ring to the right to define the setting.
• The sub-item will stop flashing. Check that the A-REC
DURATION is entered correctly.
@A-REC DURATION
A-REC P.GRADE
PRE A-REC
1M
HIGH
OFF
@A-REC DURATION
A-REC P.GRADE
PRE A-REC
15S
HIGH
OFF
By turning the JOG dial, the sub-
item of the A-REC DURATION shown on the menu
will be changed as follows:
1M 2M 5M 10M
45S 30S 15S MAN
6. Turn the JOG dial to move the cursor to A-REC P.GRADE
and turn the SHUTTLE ring to the right.
A-REC DURATION
@A-REC P.GRADE
PRE A-REC
15S
HIGH
OFF
The recording interval settings for normal record-
ing have to be set on the same menu. For details of
settings for recordings, please refer to page 33.
7. Turn the JOG dial to flash “STANDARD” and turn the
SHUTTLE ring to the right to enter the setting.
• The sub-item will stop flashing. Check that the A-REC
P.GRADE is entered correctly.
A-REC DURATION
@A-REC P.GRADE
PRE A-REC
15S
STANDARD
OFF
By turning the JOG dial, the sub-
item of the A-REC P.GRADE shown on the menu
will be changed as follows:
HIGH SUPERIOR LOW
STANDARD BASIC
8. Turn the SHUTTLE ring to the left or press the SET UP
button.
Please refer to “Setting of Alarm recording cam-
era” on page 39 for details of the cameras to be
activated when alarm recording is activated.
INFORMATION
Please refer to “Alarm Recording
operation” on page 45 for details of the alarm re-
cording.
♦ Pre-alarm recording setting
During alarm recording, it is possible to record the picture
several seconds before the signal is input in to the ALARM
IN terminal.
The USER KEY can be used to set the pre-alarm
recording on/off. Refer to page 25 for details.
Example: Set the PRE A-REC to “LONG” (the default set-
ting is “OFF”).
1. Make settings for A-REC P.GRADE, A-REC INTERVAL and
A-REC DURATION as shown on page 33 and this page.
A-REC DURATION
@A-REC P.GRADE
PRE A-REC
15S
STANDARD
OFF
2. Turn the JOG dial to move the cursor to PRE A-REC and
turn the SHUTTLE ring to the right to flash the sub-item.
A-REC DURATION
A-REC P.GRADE
@PRE A-REC
15S
STANDARD
OFF
3. Turn the JOG dial to flash LONG, and turn the SHUTTLE
ring to the right. The unit will be in stand-by mode for the
Pre-alarm recording.
• PRE ALARM REC indicator on the front of the unit will start
illuminating.
A-REC DURATION
A-REC P.GRADE
@PRE A-REC
15S
STANDARD
LONG
By turning the JOG dial, the sub-item of PRE A-
REC will be changed as follows:
OFF SHORT
LONG MIDDLE
4. Ground the ALARM IN terminal.
• The unit will start alarm recording.
The duration of recording before the ALARM IN
terminal is triggered depends on the A-REC INTER-
VAL, A-REC P.GRADE, and PRE A-REC settings.
Please refer to “Pre-alarm Recording” on page 46
for details.
INFORMATION
To activate pre-alarm recording on
Timer programmes, please refer to “Pre-alarm Re-
cording” on page 46.
Following the end of Pre-alarm recording, the regular value
of the Alarm Recording settings returns to the value set in
the A-REC P.GRADE, A-REC INTERVAL, and A-REC DU-
RATION settings.
Pre-alarm
recording
Alarm
recording
LONG/MIDDLE/SHORT of
PRE A-REC
A-REC P.GRADE/
A-REC INTERVAL
A-REC P.GRADE/
A-REC INTERVAL/
A-REC DURATION
Recording
Mode
Effective
recording
setting
Alarm input
(ALARM IN signal)