D-106
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Optical Cards
LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent.
LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent.
OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
OPT-LOW Optical power transmitted minimum. Cisco default is (15 min): 80 percent.
OPR-HIGH Optical power received maximum. Cisco default is (15 min): 200 percent.
OPR-LOW Optical power received minimum. Cisco default is (15 min): 50 percent.
Set OPR Setting the optical power received (OPR) establishes the received power level as 100 percent. If the
receiver power decreases, then the OPR percentage decreases to reflect the loss in receiver power. For
example, if the receiver power decreases 3 dBm, the OPR decreases 50 percent.
Physical Thresh 1 Day
Port No. Port number.
LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent.
LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent.
OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
OPT-LOW Optical power transmitted minimum. Cisco default is (15 min): 80 percent.
OPR-HIGH Optical power received maximum. Cisco default is (15 min): 200 percent.
OPR-LOW Optical power received minimum. Cisco default is (15 min): 50 percent.
Set OPR Setting the optical power received (OPR) establishes the received power level as 100 percent. If the
receiver power decreases, then the OPR percentage decreases to reflect the loss in receiver power. For
example, if the receiver power decreases 3 dBm, the OPR decreases 50 percent.
RS Thresh 15 Minutes
Port Number The port number
EB-RS Errored block–regenerator section
BBE-RS Background block errors–regenerator section
ES-RS Errored seconds–regenerator section
SES-RS Severely errored seconds–regenerator section
UAS-RS Unavailable seconds–regenerator section
OFS-RS Out of framing seconds–regenerator section
RS Thresh 1 Day
Port Number The port number
EB-RS Errored block–regenerator section
BBE-RS Background block errors–regenerator section
ES-RS Errored seconds–regenerator section
SES-RS Severely errored seconds–regenerator section
UAS-RS Unavailable seconds–regenerator section
OFS-RS Out of framing seconds–regenerator section
Alarm Thresholds
Table D-109 Field Descriptions for the Line Tab (continued)
Field Description