Cisco Systems 78-17630-01 TV Cables User Manual


 
D-259
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards
D.5.13.7 Output Power Tab
The Output Power tab allows you to assign performance monitoring thresholds for the receive
transponder output power.
Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the
bottom of the window.
D.5.14 Slot Properties—Transmitter Transponder
The Slot Properties pane displays information about the Cisco ONS 15808 module that is installed in the
slot selected in the NE Explorer tree. Use this properties pane to change the module performance
monitoring thresholds.
The transmitter transponder performs 3R regeneration of the 2.5 Gbps and 10 Gbps optical signal and
provides client signal validation parameters. The module transposes input client signals to appropriate
wavelengths and transmits them to the multiplexing section of the ONS 15808 system. Transmitter
transponder modules add out-of-band forward error correction (OOB-FEC) signal encoding to the client
signal to improve signal quality and transport distance.
A block diagram is shown in the following figure.
Table D-325 Field Descriptions for the Input Power Tab
Field Description
Input Power
Value When the Update button is clicked, displays the current receive transponder input power.
Low Sets the low threshold for the receive transponder input power in dBm and the alarm severity level.
High Sets the high threshold for the receive transponder input power (in dBm) and the alarm severity level.
Fail Sets the failure threshold for the receive transponder input power (in dBm) and the alarm severity level.
Table D-326 Field Descriptions for the Output Power Tab
Field Description
Output Power
Value When the Update button is clicked, displays the current receive transponder output power.
Low Sets the low threshold for the receive transponder output power (in dB) and the alarm severity level.
High Sets the high threshold for the receive transponder output power (in dB) and the alarm severity level.