Transponder Cards
D.5.1.4 Receive Direction Tab
The Receive Direction tab allows you to configure the BT10E-LCxx and BT10E-LLxx receive direction
properties. The Receive Direction tab contains the following subtabs:
D.5.1.4.1 Input Power Subtab, page D-217
D.5.1.4.2 Output Power Subtab, page D-217
D.5.1.4.3 QoS 15 Min and QoS 1 Day Subtabs, page D-217
D.5.1.4.1 Input Power Subtab
The Input Power subtab allows you to assign thresholds and alarm severities for the power coming into
the transponder lasers.
D.5.1.4.2 Output Power Subtab
The Output Power subtab allows you to assign thresholds and alarm severities for the transponder output
power.
D.5.1.4.3 QoS 15 Min and QoS 1 Day Subtabs
The QoS 15 Min and QoS 1 Day subtabs allow you to assign thresholds and alarm severities for quality
of service (QoS) counters. Click the QoS 15 min tab to assign thresholds for 15-minute collection
increments. Click the QoS 1 day tab to assign thresholds for 24-hour collection increments. The two tabs
have identical fields.
Table D-247 Field Descriptions for the Input Power Subtab
Field Description
Input Power 1
Value When the Update button is clicked, displays the current transponder input power (in dBm).
Fail Sets the failure threshold for the input power, in dBm, and the alarm severity level.
Low Sets the low threshold for the input power, in dBm, and the alarm severity level.
High Sets the high threshold for the input power, in dBm, and the alarm severity level.
Table D-248 Field Descriptions for the Output Power Subtab
Field Description
Output Power 1
Value When the Update button is clicked, displays the current transponder output power (in dBm).
Fail Sets the failure threshold for the output power, in dBm, and the alarm severity level.
Low Sets the low threshold for the output power, in dBm, and the alarm severity level.
High Sets the high threshold for the output power, in dBm, and the alarm severity level.