Cisco Systems 78-17630-01 TV Cables User Manual


 
D-38
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Multirate Cards
Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the
bottom of the window.
D.3.2 Slot Properties—MRC-12
The Slot Properties pane displays information about the Cisco ONS 15454 SONET and ONS 15454 SDH
slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance
monitoring thresholds.
The MRC-12 multirate card (MRC) provides up to 12 OC-3/STM-1 ports, 12 OC-12/STM-4 ports, or 4
OC-48/STM-16 ports using Small Form-factor Pluggables (SFPs), in any combination of line rates. All
ports are Telcordia GR-253 compliant. The SFP optics can use SR, IR, LR, coarse wavelength division
multiplexing (CWDM), and DWDM SFPs to support unrepeated spans.
The ports operate at up to 2488.32 Mbps over a single-mode fiber. The MRC-12 card has 12 physical
connector adapters with 2 fibers per connector adapter (Tx and Rx). The card supports VT payloads,
STS-1 payloads, and concatenated payloads at STS-3c, STS-6c, STS-9c, STS-12c, STS-18c, STS-24c,
STS-36c, or STS-48c signal levels. It is fully interoperable with the ONS 15454 G-Series Ethernet cards.
The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1+1 protection
in 4-fiber BLSR applications for the ONS 15454 SONET and in 4-fiber MS-SPRing applications for the
ONS 15454 SDH, where both span switching and ring switching might occur. You can provision this
card as part of a BLSR, UPSR, or 1+1 linear configuration for the ONS 15454 SONET or an MS-SPRing,
SNCP, or linear configuration for the ONS 15454 SDH.
Note Longer distances are possible in an amplified system using dispersion compensation.
Note MRC-12 cards can only protect another MRC-12 card if the card is in the same speed slot (drop or trunk
slot) and if both ports have matching line rates. For example, port 1 of the MRC-12 card 1 will protect
port 1 of the MRC-12 card 2 only if both ports are provisioned with the same rate (for example,
OC12/STM-4). If the ports are provisioned with different rates, you cannot set a 1+1 protection.
You can install MRC-12 cards in Slots 1 through 6 and 12 through 17 with an XCVT, XC10G,
XC-VXL-2.5G, XC-VXL-10G, or XC-VXC-10G card.
Note The MRC-12 card supports an errorless software-initiated cross-connect card switch when used in a
shelf equipped with XC-VXL-2.5G, XC-VXL-10G, or XC-VXC-10G cards.
Table D-46 Field Descriptions for the Transceiver Tab
Field Description
Port No. PIM number, PPM number, Port number.
Non-normalized LBC (mA) The actual operating value of laser bias current (in mA) for the specified card port.
Non-normalized OPT (dBm) The actual operating value of optical power transmitted (in dBm) for the specified card port.
Non-normalized OPR (dBm) The actual operating value of optical power received (in dBm) for the specified card port.