Optical Cards
Table D-108 Field Descriptions for the Line Tab
Field Description
Line Config
Port Number Displays the optical port number.
Port Name Allows you to enter the name of the optical port.
Admin State Displays the status of the line. The line can be In Service (IS), In Service–Auto In Service Soak
(IS_AINS), Out of Service (OOS), or Out of Service–Maintenance (OOS_MT).
Service State Overall availability of the entity. Values are:
IS_NR—In Service–Normal.
OOS_AU—Out of Service–Autonomous.
OOS_MA—Out of Service–Management.
OOS_AUMA—Out of Service–Autonomous and Management.
In addition, a secondary state provides additional information about the status of the entity. Values
for secondary state are:
MEA—Mismatch of equipment due to invalid equipment insertion.
UEQ—Unequipped. There is nothing in the slot.
UAS—Unassigned. The entity does not exist, has not been created, or has been deleted.
SWDL—Software download in progress.
MT—Maintenance, as per the Admin State change.
AINS—Automatic In Service.
DSBLD—Traffic is disabled on the entity.
LPBK—Port or connection has a loopback on it.
FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment and
ports in FLT state should be cleared as they transition. Transition states are listed in Table 11-10
on page 11-15.
See Table 11-10 on page 11-15 for the Service state/Secondary state possible values.
Note If the NE release does not support the Service state, this field shows N/A.
SF BER Sets the signal fail bit error rate.
SD BER Sets the signal degrade bit error rate.
ProvidesSync If checked, the card is provisioned as an NE timing reference.
EnableSyncMsg Enables synchronization status messages (S1 byte), which allow the node to choose the best timing
source.
Send DoNotUse When checked, sends a do not use (DUS) message on the S1 byte.
BLSR Ext. Byte Select an alternate BLSR byte. Choices are Z2, E2, or F1.
Type Defines the port as SONET or SDH.
AINS Soak Automatic in-service soak. The determination of duration left before the traffic/termination
transitions to IS state.
AINS Soak Count
Down
Automatic in-service soak countdown. Displays the remaining time of valid input signal in hh:mm,
after which the card becomes in service (IS) automatically.