Cisco Systems 78-17630-01 TV Cables User Manual


 
D-98
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Optical Cards
Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to
automatically provision the reach from the PPM reach value on the hardware. Choose one of the
following reach distances:
Note The reach distances options that appear in the drop-down list depend on the card selected.
SR (short reach, up to 2km distance)
SR 1 (up to 2km distance)
IR 1 (intermediate reach, up to 15km distance)
IR 2 (up to 40kmm distance)
LR 1 (long reach, up to 40km distance)
LR 2 (up to 80km distance)
LR 3 (up to 80km distance)
I1
S1
S2
L1
L2
L3
SX (up to 550m or 270m distance based on 50um/62.5um diameter fiber)
LX (up to 10km or 550m distance based on 50um/62.5um diameter fiber)
CX
T
DX (up to 40km distance)
HX (up to 40km distance)
ZX (up to 80km distance)
VX (up to 100km distance)
Wavelength Allows you to provision the wavelength frequency.
Line Thresh 15 Minutes
Near End
Port Number The optical port number
ES-L Errored seconds–line
SES-L Severely errored seconds–line
CV-L Coding violations–line
UAS-L Unavailable seconds–line
FC-L Failure count–line
PSC Protection switching count—Near-end only
PSD Protection switching duration—Near-end only
Table D-108 Field Descriptions for the Line Tab (continued)
Field Description