D-207
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Optical Cards
Service State Displays the service state:
• IS_NR—In Service–Normal.
• OOS_AU—Out of Service–Autonomous.
• OOS_MA—Out of Service–Management.
• OOS_AUMA—Out of Service–Autonomous and Management.
In addition, a secondary state provides additional information about the status of the entity.
Values for secondary state are:
• MEA—Mismatch of equipment due to invalid equipment insertion.
• UEQ—Unequipped; there is nothing in the slot.
• UAS—Unassigned; the entity does not exist, has not been created, or has been deleted.
• SWDL—Software download in progress.
• MT—Maintenance, as per the Admin State change.
• AINS—Automatic in service.
• DSBLD—Traffic is disabled on the entity.
• LPBK—Port or connection has a loopback on it.
• FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment
and ports in FLT state should be cleared as they transition. Transition states are listed in
Table 11-10 on page 11-15.
See Table 11-10 on page 11-15 for the Service state/Secondary state possible values.
Note If the NE does not support the Service State, this field shows N/A.
Synchronization Status
Message
SDH protocol that communicates information about the quality of the timing source.
MS-SPRing Ext. Byte Select an alternate MS-SPRing byte.
Type Defines the port.
MS Thresh 15 Min (Near End)
Port Number The port number
EB-MS Errored block–multiplex section
ES-MS Errored seconds–multiplex section
SES-MS Severely errored seconds–multiplex section
BBE-MS Background block errors–multiplex section
UAS-MS Unavailable seconds–multiplex section
PSC Protection switching count
PSD Protection switching duration
PSC-W Protection switching count–working
PSD-W Protection switching duration–working
MS Thresh 15 Min (Far End)
Port Number The port number
Table D-233 Field Descriptions for the Line Tab (continued)
Field Description