D-138
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Optical Cards
D.4.8.3 Line Tab
The Line tab allows you to view and update OC48 IR 1310 optical line performance monitoring
information.
Service State Overall availability of the entity. Values are:
IS_NR—In Service–Normal.
OOS_AU—Out of Service–Autonomous.
OOS_MA—Out of Service–Management.
OOS_AUMA—Out of Service–Autonomous and Management.
In addition, a secondary state provides additional information about the status of the entity.
Values for secondary state are:
MEA—Mismatch of equipment due to invalid equipment insertion.
UEQ—Unequipped. There is nothing in the slot.
UAS—Unassigned. The entity does not exist, has not been created, or has been deleted.
SWDL—Software download in progress.
MT—Maintenance, as per the Admin State change.
AINS—Automatic In Service.
DSBLD—Traffic is disabled on the entity.
LPBK—Port or connection has a loopback on it.
FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment
and ports in FLT state should be cleared as they transition. Transition states are listed in
Table 11-10 on page 11-15.
See Table 11-10 on page 11-15 for the Service state/Secondary state possible values.
Note If the NE release does not support the Service state, this field shows N/A.
Equipment State Displays the equipment state of the card.
Alarm Profile Sets the alarm profile for the port. Check the Suppress Alarms check box to suppress all
alarms for this card and its port(s).
Table D-145 Field Descriptions for the Identification Tab (continued)
Field Description
Table D-146 Field Descriptions for the Line Tab
Subfield Description
Line Config
Port Number Displays the optical port number.
Port Name Allows you to enter the name of the optical port.
SD BER Sets the signal degrade bit error rate.
SF BER Sets the signal fail bit error rate.
Type Defines the port as SONET or SDH.