Honeywell HRHD 410 DVR User Manual


 
Configuration
Rev 3.01 29 Document 900.0315
10/05
To change the time format, highlight the box beside Time Format and then press # .
The DVR toggles between 12 Hours (AM/PM) and 24 Hours (military time).
To save your changes, highlight OK and then press # . Select Cancel to exit the screen
without saving the changes.
System Check Screen
Use the System Check screen to check the status (fault condition) of the DVR. Highlight
System Check in the Main Menu (MENU System System Check) and then
press # . The System Check setup screen displays.
Figure 3-11 System Check Screen
1. Highlight the box under the On/Off heading and then press # . This toggles
between On and Off.
When it is On, the DVR reports a fault condition if it does not detect any recording
or if there is an alarm during the designated time.
2. Highlight the box under the Interval heading and then press # . A slide bar
displays allowing you to set the check interval from 1 Hour to 30 Days by using
the Left and Right Arrow buttons.
3. The Status field displays the fault conditions.
Good means that there was recording or an alarm occurred during the
designated time.
Bad indicates that there was no recording or no alarm occurred during the
designated time.
4. Highlight the box beside the On Record Problem: Alarm Out/Notify and then
press # . A drop-down list displays the available alarm outputs for the recording
problem. Highlight the desired alarm output(s) from No Alarm Output, External
Alarm Out Terminal, Internal Buzzer or Notify, and then press # .