Basic User:
Lets you create a dedicated surveillance system user
account with simple user name and password
authentication for each individual user.
Windows User:
Do not select this option normally. Consult your system
administrator.
When the host name is modified with [OS setting], please
enter “Administrator” in the [Enter the selected object
name] of the [Select user or group] window and click the
[Check Names] button. And then, click the [OK] button.
CAUTION
Windows users need to define the Windows user for each
host name specified in [Host Name] in [OS Setting]. As
the user’s host name is not displayed in the [User
Administration] window, to modify the host name, it is
recommended to first remove the Windows user and then
add the Windows user.
Note
To edit an existing user name or password, select the
required user in the [Current users/groups] list, and click
the [Change password] button.
To remove a user from the [User administration] window’s
list of users, select the user in the list and click the
[Delete] button. When removed from the list, the user will
no longer be able to log in with the VR-N900 Viewer.
When the user is added with [Add new user], small icon of
the user is displayed on the top left of the [User
administration] window. When the same user name is
registered to the [Basic User] and [Windows User], it can
be distinguished by this user icon.
Full Access for All Users:
Select this option to give all the users access to all VR-
N900 Viewer features and all available cameras.
Restricted Access:
Select this option to use restricted access. Then click the
[User Access] button to define access rights for each user.
Log Files Section
This section is for specifying the number of days to keep log
files in the [Image Server]’s regular event log. By default,
such log files are kept for ten days.
Audit Log Section
Audit log is the logging of client user actions.
Days to log:
Number of days in which audit log files should be kept
before they are deleted. Default is 30 days.
Minimum Logging Interval:
Minimum number of seconds between logged events.
In Sequence Times pan:
Maximum number of seconds to pass for viewed images
to be considered to be within the same sequence.
Language Support and XML Encoding Section
This section is for selecting one of the available languages.
Select a language for use in camera names, user names,
passwords, etc. Select the language of your choice.
CAUTION
The default setting of the language is set as Western
Europe, always set the language to the area you are at.
Failure to heed this caution may cause a malfunction.
Note
Log information may be required when dealing with
malfunctions.