VM200 & MIDI
190 VM200 User’s Guide
Manual transmission of Bulk Dump Messages
1. Press the [MIDI] key six times (from start of cycle).
The VM200 displays the 6:BULK DUMP function page.
2. Press the [ENTER] key.
The VM200 starts transmitting Bulk Dump Data to the connected
MIDI device and displays the following message:
“WARNING! Transmit Bulk Dump Data Now...”
Specifying the data you want to transfer
1. Press the [MIDI] key six times (from start of cycle).
The VM200 displays the 6: BULK DUMP function page.
2. Rotate the EQ/LO GAIN rotary control to adjust the Item
parameter.
This parameter specifies the data you want the VM200 to trans-
fer.
3. Rotate the EQ/LO-MID GAIN rotary control to adjust the
Block parameter.
This parameter specifies the block of data you want the VM200 to
transfer. The Block parameter is available only if you select
SETUP, SCENE, EFF LIB, or EQ LIB for the Item parameter.
4. Rotate the EQ/HI-MID GAIN rotary control to adjust the
Interval parameter.
The Interval parameter specifies the interval between data blocks
during Bulk Dump transmission.
Warning: Do not power off the VM200 while it is transmitting data or
you may damage the system or the connected MIDI device.
Item Contents Block
ALL (default)
All items listed in this table N/A
SETUP
VM200 all current setup data ALL, SYSTEM, MIDI, LOC MEM
SCENE
Scene memories ALL, CURRENT, 00–99
EFF LIB
Effect library user programs ALL, 50–99