Pad Switches (Input channels 1–4)
VM200 UserÕs Guide
63
Pad Switches (Input channels 1–4)
Input channels 1 through 4 feature 26 dB Pad switches that attenu-
ate the input signal by 26 dB.
This allows the input preamp to work with hot, high-level signals,
such as those from a snare drum microphone.
TRIM Controls
You can adjust the gain of the input channel preamps on input chan-
nels 1 through 4 by using the Trim controls. Your goal is to optimize
the input signal level to achieve the best signal-to-noise ratio.
Keep a close eye on the level meters while adjusting the Trim controls.
In general, set the levels as high as possible without peaking (actually,
it’s okay if the level
occasionally
peaks a little). If you set the level too
high, the signal may distort and or clip. If it’s set too low, the output
signal may sound thin or noisy.
The Trim controls have an input sensitivity of –16 dB to –60 dB,
which is appropriate for many microphones. However, you can press
one of the Pad switches for channels 1–4 to reduce the input sensitiv-
ity for that channel to the range of +10 to –34 dB. This works well for
“hot” microphone signals.
The Trim controls on input channels 5–8 have a gain range of –10 dB
to –50 dB. This works well with line-level signals.
PAD
26dB
PAD
26dB
PAD
26dB
PAD
26dB
Note: Pad switch settings are not stored in Scene Memory.
INPUT 4INPUT 3INPUT 2INPUT 1
PAD
26dB
PAD
26dB
PAD
26dB
A
B
A
B
A
B
A
B
PAD
26dB
-16
-60
+10
-34
-16
-60
+10
-34
-16
-60
-16 -60
TRIMTRIMTRIMTRIM TRIM
-10 -50
TRIM TRIM TRIM
-10 -50
-10 -50
-10 -50
INPUT 5 INPUT 6 INPUT 7 INPUT 8
+10
-34
+10
-34
VM200 uses “boxed” values
when Pad switch is depressed.
Note: Trim control settings are not stored in Scene Memory.