Galil DMC-13X8 Home Theater Server User Manual


 
USER MANUAL Chapter 8 Hardware & Software Protection 149
Chapter 8 Hardware & Software
Protection
Introduction
The DMC-13X8 provides several hardware and software features to check for error conditions and to
inhibit the motor on error. These features help protect the various system components from damage.
WARNING: Machinery in motion can be dangerous! It is the responsibility of the user to design
effective error handling and safety protection as part of the machine. Since the DMC-13X8 is an
integral part of the machine, the engineer should design his overall system with protection against a
possible component failure on the DMC-13X8. Galil shall not be liable or responsible for any
incidental or consequential damages.
Hardware Protection
The DMC-13X8 includes hardware input and output protection lines for various error and mechanical
limit conditions. These include:
Output Protection Lines
Amp Enable - This signal goes low when the motor off command is given, when the position error
exceeds the value specified by the Error Limit (ER) command, or when off-on-error condition is
enabled (OE1) and the abort command is given. Each axis amplifier has separate amplifier enable
lines. This signal also goes low when the watch-dog timer is activated, or upon reset. Note: The
standard configuration of the AEN signal is TTL active low. Both the polarity and the amplitude can
be changed if you are using the ICM-1900 interface board. To make these changes, see section
entitled ‘Amplifier Interface’ pg 3-26.
Error Output - The error output is a TTL signal which indicates an error condition in the controller.
This signal is available on the interconnect module as ERROR. When the error signal is low, this
indicates one of the following error conditions:
1. At least one axis has a position error greater than the error limit. The error limit is set by using the
command ER.
2. The reset line on the controller is held low or is being affected by noise.
3. There is a failure on the controller and the processor is resetting itself.
4. There is a failure with the output IC which drives the error signal.