1
2 GND
IN
REC IN GND
TIME ADJ IN
TAPE END OUT
RESET
ALARM
EXT
TIMER
OUT
IN
OUT
WARNING
/REC OUT
+
Terminal connections
As shown below, firmly twist the end of the cord which
is to be connected to the terminal section.
External alarm lamp
External alarm buzzer
Alarm reset
switch
4V to 5V
Alarm switch 1
When an alarm signal is input to
ALARM IN 1, alarm recording or
sensor recording is performed.
Alarm switch 2
When an alarm signal is input to
ALARM IN 2, alarm recording or
sensor recording is performed.
External interface
Firmly twist or
solder here.
When connecting or disconnecting the
cord, press this part down using a
regular screwdriver.
Solid wire : 0.4 to 1.2 mm diameter
Twisted wire : 0.3 to 1.25 mm
(The diameter of the strands must be
0.18 mm or more.)
O
Failure to twist the end of the cord firmly can cause
short-circuiting.
Alarm recording connections
O
When alarm recording has been set for MODE on
the menu screen shown on P4 ALARM/SENSOR
REC, alarm recording is started when the alarm
switch is set to ON.
O
Alarm recording is released when the alarm reset
switch is set to ON.