RS-232C
$
Timer control commands
These commands are not acknowledged while a search control command is being processed.
Data transmitted by PC Data returned from unit in response Description of command
[STX] TAT:data [ETX]
Parameter
data = mm:n
mm = 00—23 : Digit(s) of the hour
to be set
FF : Sets the digits for
the minutes to 00.
n = S (fixed)
[STX] TAT [ETX] Sets the time to be set when signals have been input from
the component connected to TIME ADJ IN on the rear panel
terminal section.
[STX] TCS:data [ETX]
Parameter
data = yyyymmdd
yyyy = 2000—2099:
Gregorian calendar
mm= 01—12: Month
dd = 01—31: Day
[STX] TCS [ETX] Sets the current date.
When a day which does not exist for the month or due to a
leap year has been set, error code ERE is returned from the
unit.
[STX] TTS:data [ETX]
Parameter
data = hhmmss
hh = 00—23: Hours (24-hour
system)
mm = 00—59: Minutes
ss = 00—59: Seconds
[STX] TTS [ETX] Sets the current time.