66
RS-232C
$
Display control commands
Data transmitted by PC Data returned from unit in response Description of command
[STX] DFC:m [ETX]
Parameter
m = C: (COUNT) counter display
I: (TIME) clock display
M: (CAMERA) camera number
display
P: (PASS) pass display
[STX] DFC [ETX] Sets the display mode of the display tube.
<Note>
This command is not acknowledged while a search control
command is being processed.
[STX] DBB [ETX] [STX] DBB [ETX] Sets black as the color of the characters displayed on the
monitor screen.
<Note>
This command is not acknowledged while a search control
command is being processed.
[STX] DBW [ETX] [STX] DBW [ETX] Sets white as the color of the characters displayed on the
monitor screen.
<Note>
This command is not acknowledged while a search control
command is being processed.
[STX] DDS:d:t:m:r [ETX]
Parameter
d = N or F (date)
t = N or F (time)
m = N or F (recording time mode)
r = N or F (REC/ALARM)
N: ON (displayed)
F: OFF (not displayed)
[STX] DDS [ETX] Sets the display items on the monitor screen.
<Note>
This command is not acknowledged while a search control
command is being processed.
[STX] DMS:d:m:n [ETX]
Parameter
d = T (fixed)
m = M: AM/PM display
H: 24-hour display
n = 0—9: VTR ID No.
This unit does not have a
function for displaying the VTR
ID No. so any number between
0 and 9 may be sent.
[STX] DMS [ETX] Sets the time display mode (12-hour or 24-hour system).
<Note>
This command is not acknowledged while a search control
command is being processed.
[STX] DPP:mm [ETX]
Parameter
mm = C: Center
LB: Bottom left
LT: Top left
RB:Bottom right
RT: Top right
[STX] DPP [ETX] Sets the position where the characters are to be displayed
on the monitor screen.
<Note>
This command is not acknowledged while a search control
command is being processed.