Panasonic AG-DTL1 VCR User Manual


 
98
RS-232C
$
Query control commands
Data transmitted by PC Data returned from unit in response Description of command
[STX] QSQ [ETX] [STX] LSQm:t [ETX]
Parameter
m = 0F: Camera No. 116
t = A: Auto sequence mode
M: Manual sequence mode
Queries the camera number selection and sequence mode.
[STX] QSU [ETX] [STX] LSUm [ETX]
Parameter
m = N: Daylight saving time setting ON
F: Daylight saving time setting
OFF
Queries the ON/OFF setting for daylight saving time.
[STX] QTA [ETX] [STX] TATmm:S [ETX]
Parameter
data = mm:n
mm = 0023: Digits of hours to be set
FF: Sets minute digits to 00.
n = S (fixed)
Queries the setting of the time to be set when signals have
been input from the component connected to TIME ADJ IN
on the rear panel terminal section.
[STX] QTL [ETX] [STX] TCSdata [ETX]
Parameter
data = yyyymmdd
yyyy = 20002099: Gregorian
calendar
mm= 0112: Month
dd = 0131: Day
Queries the current date setting.
[STX] QTC [ETX] [STX] TTSdata [ETX]
Parameter
data = hhmmss
hh = 0023: Hours (24-hour mode)
mm = 0059: Minutes
ss = 0059: Seconds
Queries the current time setting.
[STX] QST [ETX] [STX] LSTdata1:data2 [ETX]
Parameter
data1 = ndmmtt (start date/time)
data2 = ndmmtt (end date/time)
n = 1: 1st week
2: 2nd week
3: 3rd week
4: 4th week
L: Last week
d = 0: Sunday
1: Monday
2: Tuesday
3: Wendnesday
4: Thursday
5: Friday
6: Saturday
mm = 0112: Month
tt = 0122: Hours
Queries the start date/time and end date/time of daylight
saving time.