RS-232C
$
Time lapse control commands
These commands are not acknowledged while a search control command is being processed.
Data transmitted by PC Data returned from unit in response Description of command
[STX] LRB:m [ETX]
Parameter
m = F: Buzzer OFF
0: 5 minutes
1: 10 minutes
2: 20 minutes
3: 30 minutes
[STX] LRB [ETX] Sets the buzzer to sound a warning in the event that the
unit has been kept in the stop mode for the time designated
by the parameter.
[STX] LRI:m [ETX]
Parameter
m = A: Alarm signal input is
acknowledged.
F: Alarm signal input is
ignored.
[STX] LRI [ETX] Sets whether alarm recording or sensor recording is to be
performed if an alarm signal has been input while repeat
recording is underway or while the tape is being rewound.
[STX] LRM:m [ETX]
Parameter
m = E: External timer recording
I: Internal timer recording
N: Regular recording
[STX] LRM [ETX] Sets the timer recording mode.
[STX] LRR:m [ETX]
Parameter
m = N: REC REVIEW is performed
automatically.
F: REC REVIEW OFF
[STX] LRR [ETX] Sets REC REVIEW.
This function plays back the recording after recording for a
specific time to detect whether the proper video level is
being maintained during recording.
[STX] LSQ:m:t [ETX]
Parameter
m = 0F: Camera No.116
t = A: Auto sequence mode
M: Manual sequence mode
[STX] LSQ [ETX] Selects the camera number and sequence mode.
[STX] LST:data1:data2 [ETX]
Parameter
data1 = ndmmtt (start date/time)
data2 = ndmmtt (end date/time)
n = 1: 1st week
2: 2nd week
3: 3rd week
4: 4th week
L: Last week
d = 0: Sunday
1: Monday
2: Tuesday
3: Wendnesday
4: Thursday
5: Friday
6: Saturday
mm = 0112: Month
tt = 0122: Hours
[STX] LST [ETX] Sets the start date/time and end date/time settings for
daylight saving time.