89
RS-232C
$
Query control commands
Data transmitted by PC Data returned from unit in response Description of command
[STX] QIR [ETX] [STX] LUImdata [ETX]
Parameter
m = R: READ OK
E: READ NG
data = U
7
U
6
U
5
U
4
U
7
U
3
U
2
U
1
U
0
The user ID is returned as an 8-
character ASCII code.
Binary 4BIT
a
8
7
ASCII code: 0—9, A—F
Queries the user ID recorded on the playback tape.
[STX] QLA:m [ETX]
Parameter
m = I: Operation mode
D: Time setting
[STX] LAmn [ETX]
Parameter
m = I: Operation mode
m = D: Time setting
n = 0: 30 seconds
1: 1 minute
2: 1 minute and 30 seconds
3: 2 minutes
4: 3 minutes
5: 6 minutes
6: 10 minutes
7: CONTINUE
Recording continues until
the tape-end.
8: MANUAL
Recording is performed only
while an alarm signal is
input.
n = S: STOP
Stop mode at tape-end
position
C: CONTINUE
Alarm signal input is
ignored.
Queries the operation mode that is to be established when
an alarm signal has been input at the tape-end position, and
the duration of the alarm recording and/or sensor recording.
[STX] QIW [ETX] [STX] LIWabcdefgh:ijklmnop [ETX]
Parameter
a—p = 1—8: Program registration
number (PGM1—PGM8)
F: Timer is not set.
a = Program 1 on Sunday
b = Program 1 on Monday
c = Program 1 on Tuesday
d = Program 1 on Wednesday
e = Program 1 on Thursday
f = Program 1 on Friday
g = Program 1 on Saturday
h = Daily program 1
i = Program 2 on Sunday
j = Program 2 on Monday
k = Program 2 on Tuesday
l = Program 2 on Wednesday
m =Program 2 on Thursday
n = Program 2 on Friday
o = Program 2 on Saturday
p = Daily program 2