Panasonic AG-DTL1 VCR User Manual


 
44
Menu page P4
[RECORDING MODE] P4
FIELD/FRAME FIELD
PICTURE QUALITY HIGH
REC-TYPE RT0 ( OFF
¢
16)
[ALARM/SENSOR REC]
MODE OFF
FIELD/FRAME FIELD
PICTURE QUALITY HIGH
DURATION 0.5min
BUZZER OFF
REPEAT OFF
GROUP ALARM1 RT0 ( OFF
¢
16)
GROUP ALARM2 RT0 ( OFF
¢
16)
ALARM/SENSOR REC screen
Menu item Description of function
MODE For setting what recording operation is to be performed when an
alarm signal has been input.
OFF : The unit operates normally regardless of whether an
alarm signal is input.
ALARM/SENSOR:
Alarm recording or sensor recording is performed.
ALARM : Alarm recording is performed.
SENSOR: Sensor recording is performed.
FIELD/FRAME For selecting field recording or frame recording when alarm
recording or sensor recording is to be performed.
FIELD : Field recording is performed.
FRAME : Frame recording is performed.
PICTURE
QUALITY
For setting the picture quality when alarm recording or sensor
recording is to be performed.
HIGH : Recording is performed at a high quality.
NORMAL : Recording is performed at the standard quality.
NO CHANGE : Recording is performed at the current quality setting.
DURATION For setting the length of the alarm recording or sensor recording.
0.5min : Recording for 30 seconds.
1.0min : Recording for 1 minute.
1.5min : Recording for 1 minute and 30 seconds.
2.0min : Recording for 2 minutes.
3.0min : Recording for 3 minutes.
5.0min : Recording for 5 minutes.
10min : Recording for 10 minutes.
CONTINUE: Recording continues until the tape-end.
MANUAL : Recording is performed only while an alarm signal is
input.
BUZZER For setting whether the buzzer is to sound during alarm recording or
sensor recording.
ON : The buzzer sounds. It stops when any one of the function
buttons is pressed.
OFF: The buzzer does not sound.
GROUP ALARM1 For selecting the recording type from what was registered on menu
page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 1.
RT0RT7
GROUP ALARM2 For selecting the recording type from what was registered on menu
page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 2.
RT0
RT7
REPEAT For setting whether alarm recording or sensor recording is to be
performed if an alarm signal has been input while repeat recording is
underway or while the tape is being rewound.
OFF: Alarm recording or sensor recording is not performed when
the tape is being rewound.
If an alarm signal has been input even when tape rewinding is
completed, alarm recording or sensor recording is performed.
ON : Alarm recording or sensor recording (or both) is forcibly
performed even while the tape is being rewound.
The underlining indicates the factory mode setting.
Setting menus
<Note>
When RT7 has been selected as the REC-TYPE item setting, the
FIELD/FRAME item setting is overridden and frame recording is forcibly
initiated.