Panasonic AJ-HD1800P DVR User Manual


 
79
Function menus (continued)
<50P IN/OUT ASSIGN> (continued)
50-pin assignment factory settings
__
” denotes that nothing is subject to control or to a status.
<Notes>
z For a command, input TTL level signals; for an active low
edge, input an electrical signal of 100 ms or more.
z For a status, a maximum open collector and sink current of
6 mA is output.
Pin no. I/O Setting item
1IREC
2IPLAY
3IFF
4IREW
5ISTOP
6I
__
7I
__
8I422 REMOTE ON
9I422 REMOTE OFF
10 I LOCAL ENABLE
11 I EJECT
12 I IN SET
13 I REC INH ALL
14 I REC INH PRE
15 I LOCAL DISABLE
16 I TC EXT
17 I TC INT&TCG MODE AUTO
18 I
__
19 I
__
20 I STNDBY ON/OFF
21 O ERR0 STATUS
22 I
__
23 I CUE
24 O ERR1 STATUS
25 I
__
26
Power
supply
27 O REC STATUS
28 O PLAY STATUS
29 O FF STATUS
30 O REW STATUS
31 O STOP STATUS
32 O 422 REMOTE STATUS
33 O EJECT STATUS
34 O ERR2 STATUS
35 O TC SRC1 STATUS
36 O TC SRC2 STATUS
37 O
__
38 O
__
39 O REC INH1 STATUS
40 O REC INH2 STATUS
41 O CUE STATUS
42 O REMOTE STATUS
43 O
__
44 O PRE CTL DETECTED STATUS
Pin no. I/O Setting item
45 O LOCAL ENABLE STATUS
46 O STANDBY ON STATUS
47 GND
48 O
__
49 GND
50 GND