Panasonic WJ-FS616C Home Theater Server User Manual


 
76
Connections
In this type of installation, only one video multiplexer is con-
nected directly to the system controller by a control cable.
The rest of the video multiplexers are connected to the sys-
tem controller in a daisy-chain type connection.
Refer to the connections and data port settings shown
below.
Notes:
Up to four video multiplexers can be daisy-chained
to the system controller.
• Unit numbers should be assigned in the order of
connection, starting with the unit connected directly
to the WV-CU550C system controller.
Sequence display is limited to the cameras con-
nected to one multiplexer unit only.
• It is recommended to set the LOCK switch to the
ON position while making these connections.
For controlling more than 4 cameras, additional WV-
BP6164 Data Multiplex Boards need to be installed
in the video multiplexer.
Operating Procedure
To control the system, follow the procedure shown below.
1. Confirm that the camera and peripherals are connected
correctly and firmly.
2. Turn on the power switches of all system components.
3. Confirm that the DAISY MODE parameter in the SYS-
TEM SETUP menu is set to ON.
4. Select the unit number of the video multiplexer with the
Numeric key, then press the [MON(UNIT/ESC)] key to
activate the selected unit.
For example, press the keys shown below.
In this example, the image of camera 15 connected to
the video multiplexer Unit 2 is displayed on the Spot
Monitor connected to the video multiplexer Unit 1.
5. Operate the selected unit as described in the OPERAT-
ING PROCEDURES.
6. Select another unit with the Numeric key, then press the
[MON(UNIT/ESC)] key to activate the selected unit.
Other Applications
Application 1
The video signal looped through the SPOT IN connector
can be displayed on the Spot Monitor.
1. Confirm that the DAISY MODE in the SYSTEM SETUP
menu is set to OFF.
2. Select the unit number of the video multiplexer with the
Numeric key, then press the [MON(UNIT/ESC)] key to
activate the selected unit.
3. Press the [F2] button on the controller to select the spot
monitor.
4. Press [ 0 ] then press the [CAM(SET)] key to display the
video looped through the SPOT IN connector on the
Spot Monitor.
TEAM.
OFF
INOUT
ON
DATA
SPOT
OUT I N
TEAM.
OFF
INOUT
ON
DATA
SPOT
OUT I N
IN OUT
TERM
ON OFF
DATA
0
1
2
3
4
5
6
7
8
9
CONTROLLER
UNIT NO.
1-8
Local Site Main Site
Video Multiplexer
WJ-FS616C
Video Multiplexer
WJ-FS616C
1 2 3
4 5 6
7 8 9
MON CAM
UNIT/ESC SET
0
MON CAM
UNIT/ESC
2
SET
1 5
Unit 2
VIDEO
Unit 1
VIDEO