WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 307
Chapter 8: Specifications
High-Capacity (Model WA3006)
8.3.1.4 Safety License
8.3.1.5 Environmental Test
Reverse Charging Test
After a standard discharge,
reverse-charge continuously at
4.2V and 4A for 8hrs.
Protection circuit board to operate.
No explosion, fire, smoke, or leakage.
Item License Standard
1 UL 1642
The lithium-ion cell has been listed and pass the UL1642 stan-
dard by UL Lab.
2 UL 2054
The battery pack is in the process to apply the UL 2054 battery
standard.
3
89/336 EEC-EMC
directive.
The battery pack is in the process to apply the below standard:
-EN55022 -LVD 72/23 EEC -EN55024 -EN61326
4 RoHS Directive
The battery pack is in the process to apply the RoHS directive
applicable report by SGS Lab.
Description Test Reference Test Condition/Result
Drop (mechanical)
Drop sample battery on all faces from height of
1.2 meters onto concrete floor.
No explosion, fire, vent, leakage and the open
circuit voltage higher than 3.7V.
Storage at high temp. EN60068-2-2 Test
+60°C dry for 240 hours
No explosion, fire, vent or leakage.
Storage at low temp. EN60068-2-1 Test
-20°C dry for 240 hours
No explosion, fire, vent or leakage.
Storage at high temp.
and high humidity
IEC68-2-3 Test
+40°C at 90%RH for 240 hours.
No explosion, fire, vent or leakage.
Storage temp. cycling IEC68-2-14 Test
+60oC (2C) for 1 hour (T1), -20oC (2C) for 1
hour. 3 minutes Max allowed for change
between T1 and T2.
Cycle 10 times
No explosion, no fire, no vent, and no leakage.
Vibration resistance
BS2011 Part 2.1
FDC (IEC68-2-37)
After standard charge, tested under the following
conditions: Random vibration 5Hz-500Hz ASD
0.02g2/Hz in 3 axis for 15 mins. After which,
carry out a standard discharge, charge, discharge.
No parting joints/cracks or damage to connec-
tors. No leakage or critical damage.
Description Condition Test Condition/Result