RECORD SET3
56 English
SETTINGS
13 Press the [EXIT] button.
The setting procedure is ended and the display returns to
the normal screen.
z The recording rate is automatically calculated based on
recording settings and the number of connected
cameras, and this is indicated by “REC RATE”. All
cameras will record at this rate. If a valid figure cannot
be calculated, “ERROR!” will be displayed.
z When easy setup settings and individual settings are
both set, the most recent settings override previous
settings.
z Easy setup settings cannot be used with program
recording or day-specific timer recording.
4 Turn the jog dial to select “REC RATE
BASE”, and then turn the shuttle dial
clockwise.
The <REC RATE BASE> screen is displayed with the
cursor positioned on “REC RATE”.
The number of detected cameras is indicated by
“NUMBER OF CAMERAS”.
z Confirm that the number of cameras connected to the
digital video recorder is the same as the number of
displayed recording cameras. If this is not the case,
check the wiring between cameras and the digital video
recorder and then carry out “CAMERA DETECT”.
(JP.46)
5 Turn the shuttle dial clockwise.
“60.00” flashes.
6 Turn the jog dial to select “REC RATE”,
and then turn the shuttle dial clockwise.
Set the recording rate for each individual camera.
The cursor moves to “TIMER RECORDING (DAY)”.
7 Turn the shuttle dial clockwise.
“OFF” flashes.
8 To activate timer operation, turn the jog
dial to select “ON”, and then turn the
shuttle dial clockwise.
The cursor moves to “START”.
If timer recording has been set to “ON”, the timer’s
“START” and “STOP” should now be set.
Setting based on recording rate
EXIT
e00_l8hbe_xe_7.book Page 56 Tuesday, April 27, 2004 10:35 AM