RECORD SET3
English 73
z All sensors on the same line as the cursor can be
modified simultaneously by pressing the [MENU
RESET] button. (A → B → -)
8 Turn the jog dial to move the cursor to
“T-1”, and then turn the shuttle dial
clockwise.
“T-1” flashes.
9 Turn the jog dial to select T-1, T-2, T-3,
or T-4, and then turn the shuttle dial
clockwise.
The cursor moves to “LEVEL”.
10 Turn the shuttle dial clockwise.
“OFF” flashes for “LEVEL”.
11 Turn the jog dial to set the sensitivity
(OFF or 1 through 10), and then turn the
shuttle dial clockwise.
The cursor moves to “MODE”.
[Settings] ( indicates the default setting)
12 Turn the shuttle dial clockwise.
“A” flashes for the “MODE”.
13 Turn the jog dial to select a “MODE”,
and then turn the shuttle dial clockwise.
The mode selection is confirmed and the cursor returns to
the top left position.
[Settings] ( indicates the default setting)
14 Set “LEVEL” and “MODE” for T-2
through T-4 using the same procedure
(i.e., steps 8 through 13).
Setting Description
OFF Motion sensing is not carried out.
1 to10
Motion sensing is carried out. Lower values
correspond to higher sensitivities.
Setting Description
A
The motion sensor alarm is triggered when a
moving object is detected in A.
B
The motion sensor alarm is triggered when a
moving object is detected in B.
A AND B
The motion sensor alarm is triggered when a
moving object is detected by a sensor in both A
and B.
A AND NB
By setting A to important points (or suspected
points of motion) and setting B to non-moving
points, motion can be detected at point A even
when the overall brightness changes and in other
situations where motion at both A and B would
normally be detected.
A TO B
The motion sensor alarm is triggered when an
object is detected moving from A to B. (within 2
seconds from A to B)
B TO A
The motion sensor alarm is triggered when an
object is detected moving from B to A. (within 2
seconds from B to A)
C
A motion sensor alarm is triggered when the
entire image changes uniformly. In this way,
sprays and other similar measures can be
protected against. (No sensor settings are
needed for this mode.)