2-71
Cable Connections
Connecting the Control Panel to Source Power
1. Open the control panel lid and check to see that the power switch
(located on the left side of the tub) is in the OFF position.
2. Connect the power cable from the back of the control panel to source
power. Do NOT turn control panel power on at this time.
3. Verify you have received the correct power cable. For use in Europe,
the power cables must be TUV approved. The control panel power
cable should be a molded grounding connector (IEC 320-C13) on one
end with pigtails on the other.
4. For use in the United States, Canada, South America and Southeast
Asia, a standard 110VAC power cable is supplied for the control panel.
It has a molded grounding plug (NEMA 5-15P) at one end and a
molded grounding connector (IEC 320-C13) at the other end.
Switcher Power Supply Connections
1. Ensure that the power switch located on the front of the switcher power
supply is in the OFF position.
2. Connect the power cable from the rear of the switcher power supply to
an appropriate source of 220VAC power. Refer to Table 1-1 on
page 1-11 for power requirements.
3. Make sure you have the correct power cable. For use in Europe you
should have received a power cable with pigtails on the free end. For
use in the U.S., Canada, South America and Southeast Asia the power
cable should have a 20 Amp Twist-Lock 240 VAC NEMA Type l6-20P
plug attached.
4. If a redundant switcher power supply is installed, connect it to a
separate 220 VAC power source (branch circuit).