Emerson Process Management Rev AB Projection Television User Manual


 
Option Description
Informa-
tional
Actions when fault is detected:
The alert is posted to the Alert List.
The status LED (if available) changes to red or yellow (depending on alert se-
verity).
Actions when alert clears:
The status LED returns to green.
Status alerts and options for Status Alert Severity
Status alerts and Status Alert SeverityTable 5-1:
Alert number Alert title Default severity User can reset severity
A001 EEPROM Error Fault No
A002 RAM Error Fault No
A003 No Sensor Response Fault Yes
A004 Temperature Overrange Fault No
A006 Characterization Required Fault Yes
A008 Density Overrange Fault Yes
A009 Transmitter Initializing/Warm-
ing Up or Significant Process
Instability
Ignore Yes
A010 Calibration Failure Fault No
A014 Transmitter Failure Fault No
A016 Sensor Temperature (RTD)
Failure
Fault Yes
A020 Calibration Factors Missing Fault Yes
A021 Transmitter/Sensor/Software
Mismatch
Fault No
A029 Internal Electronics Failure Fault No
A030 Incorrect Board Type Fault No
A033 Insufficient Pickoff Signal Fault Yes
A036 Viscosity Overrange Fault No
A037 Sensor Check Failed Fault Yes
A038 Time Period Signal Out of
Range
Fault No
A100 mA Output 1 Saturated Informational To Informational or Ignore only
A101 mA Output 1 Fixed Informational To Informational or Ignore only
A102 Drive Overrange Informational Yes
A104 Calibration in Progress Informational To Informational or Ignore only
A105 Two-Phase Flow Informational Yes
Configure device options and preferences
94 Micro Motion
®
Fork Viscosity Meters (FVM)