Options for Pressure Measurement Unit (continued)Table 4-3:
Unit description
Label
Display ProLink III Field Communicator
Millimeters water @ 4 °C mmW4C mm Water @ 4°C mmH2O @4DegC
Millimeters water @ 68 °F mmH2O mm Water @ 68°F mmH2O
Millimeters mercury @ 0 °C mmHG mm Mercury @ 0°C mmHg
Inches mercury @ 0 °C INHG In Mercury @ 0°C inHG
Pounds per square inch PSI PSI psi
Bar BAR bar bar
Millibar mBAR millibar mbar
Grams per square centimeter G/SCM g/cm2 g/Sqcm
Kilograms per square centimeter KG/SCM kg/cm2 kg/Sqcm
Pascals PA pascals Pa
Kilopascals KPA Kilopascals kPa
Megapascals MPA Megapascals MPa
Torr @ 0 °C TORR Torr @ 0°C torr
Atmospheres ATM atms atms
4.6 Configure referred viscosity measurement
Referred viscosity is line viscosity corrected to a reference temperature. In other words, this
is the viscosity that the device would report if the line temperature matched the reference
temperature.
Three methods are available to calculate referred viscosity. These methods are described
in the following table.
Configuration methods for referred viscosityTable 4-4:
Referred viscosity calculation
method Description
ASTM D341 Single-Curve Based on ASTM D341 standards
Applicable only to petroleum products
Used when the meter will measure only one process fluid
ASTM D341 Multi-Curve Based on ASTM D341 standards
Applicable only to petroleum products
Supports measurement of two to eight process fluids from
one configuration
Configure process measurement
Configuration and Use Manual 35