Honeywell HRXD9 DVR User Manual


 
Configuration
Document 900.0856 Rev 3.00 75
11/07
4. You can accept the Archive Data Range by leaving the default checkmarks in the
Last Archived and Continue boxes. If you wish to enter specific times and dates
in From and To, toggle the checkmarks Off and then enter the time and date.
5. Highlight Recycle and press to toggle between On and Off. When Recycle is
On and the storage device is full, the newest archived video data will overwrite the
oldest archived data. When Recycle is Off, the DVR will stop archiving video data
until more space is made available.
6. Highlight Summary Archive and press to toggle between On and Off. When
Summary Archive is On, the DVR does not archive recorded video in full, but
archives one image per 16 images from each channel. This will allow the DVR to
archive more recorded video and increase archive speed as well.
Note The archiving speed might be slower than the recording speed
when a large quantity of recorded data is being archived. In this
case, the old data can be overwritten by the latest data being
recorded. To prevent unwanted data overwriting please use the
Summary Archive function, or set the recorded image quality to
Standard during the archiving process.
7. You can save your changes by highlighting Save and pressing . Selecting
Cancel exits the screen without saving the changes.
Event Settings
Your DVR can be set to detect many different events. You can also determine how it
reacts to these events.
Figure 3-54 Event Menu